You should always use the following client startup parameters for a Dynamics development session:

   -inp      18000       # max-statement-len
   -mmax     65534       # max-r-code-memory
   -tok      1600        # max-tokens
   -zn                   # compile underscore files

Regards,
Tom

Harvey Willensky wrote:

When attempting to create or edit a data logic procedure using I am getting the following error:

Error occurred while accessing component property/method: LoadControls,

Not enough storage is available to complete this operation.

Error code 0x800700e control_load adeuib/_tview.w (5890)

The same error appears if I try to create a PLIP.

This is on Posse Version 3.0 Baseline 3.

Do I need to change some startup parameters?Any suggestions?

Thanks

--
Tom Nordhougen
Progress Software Corp.
http://www.progress.com
---------------------------------------------------------->
The art of progress is to preserve order amid change, and
to preserve change amid order. -Alfred North Whitehead